PowerControl & PowerAssist- Yes
Transfer Switch- 50A
Parallel and 3-Phase Operation- Yes
INVERTER
Input Voltage Range-
-
12/2000/80-50 = 9.5V - 17V
-
24/2000/50-50 = 19V - 33V
-
12/3000/120-50 = 9.5V - 17V
-
24/3000/70-50 = 19V - 33V
Output Voltage- 120VAC ± 2%
Output Frequency- 60Hz ± 0.1%
Cont. Output Power at 25°C³-
-
12/2000/80-50 = 2000VA
-
24/2000/50-50 = 2000VA
-
12/3000/120-50 = 3000VA
-
24/3000/70-50 = 3000VA
Cont. Output Power at 25°C-
-
12/2000/80-50 = 1600W
-
24/2000/50-50 = 1600W
-
12/3000/120-50 = 2400W
-
24/3000/70-50 = 2400W
Cont. Output Power at 40°C-
-
12/2000/80-50 = 1450W
-
24/2000/50-50 = 1450W
-
12/3000/120-50 = 2200W
-
24/3000/70-50 = 2200W
Cont. Output Power at 65°C-
-
12/2000/80-50 = 1100W
-
24/2000/50-50 = 1100W
-
12/3000/120-50 = 1700W
-
24/3000/70-50 = 1700W
Peak Power-
-
12/2000/80-50 = 4000W
-
24/2000/50-50 = 4000W
-
12/3000/120-50 = 6000W
-
24/3000/70-50 = 6000W
Maximum Efficiency-
-
12/2000/80-50 = 92%
-
24/2000/50-50 = 94%
-
12/3000/120-50 = 93%
-
24/3000/70-50 = 94%
Zero Load Power-
-
12/2000/80-50 = 9W
-
24/2000/50-50 = 11W
-
12/3000/120-50 = 20W
-
24/3000/70-50 = 20W
Zero Load Power In AES Mode-
-
12/2000/80-50 = 7W
-
24/2000/50-50 = 8W
-
12/3000/120-50 = 15W
-
24/3000/70-50 = 15W
Zero Load Power In Search Mode-
-
12/2000/80-50 = 3W
-
24/2000/50-50 = 4W
-
12/3000/120-50 = 8W
-
24/3000/70-50 = 10W
CHARGER
AC Input Voltage Range- 95 - 140VAC
AC Input Frequency- 45 - 65Hz
Power Factor- 1
Charge Voltage 'Absorption'-
-
12/2000/80-50 = 14.4V
-
24/2000/50-50 = 14.4V
-
12/3000/120-50 = 28.8V
-
24/3000/70-50 = 28.8V
Charge Voltage 'Float'-
-
12/2000/80-50 = 13.8V
-
24/2000/50-50 = 13.8V
-
12/3000/120-50 = 27.6V
-
24/3000/70-50 = 27.6V
Storage Mode-
-
12/2000/80-50 = 13.2V
-
24/2000/50-50 = 13.2V
-
12/3000/120-50 = 26.4V
-
24/3000/70-50 = 26.4V
Charge Current House Battery-
-
12/2000/80-50 = 80A
-
24/2000/50-50 = 50A
-
12/3000/120-50 = 120A
-
24/3000/70-50 = 70A
Charge Current Starter Battery- 4A
Battery Temperature Sensor- Yes
GENERAL
Auxiliary Output-
-
12/2000/80-50 = N.A.
-
24/2000/50-50 = N.A.
-
12/3000/120/50 = Yes 32A
-
24/3000/70-50 = Yes 32A
Programmable Relay-
-
12/2000/80-50 = Yes 1x
-
24/2000/50-50 = Yes 1x
-
12/3000/120-50 = Yes 3x
-
24/3000/70-50 = Yes 3x
Protection- a - g
VE.Bus Communication Port- For parallel and three phase operation, remote monitoring and system integration
General Purpose Com. Port-
-
12/2000/80-50 = N.A.
-
24/2000/50-50 = N.A.
-
12/3000/120-50 = Yes 2x
-
24/3000/70-50 = Yes 2x
Remote On/Off- Yes
Operating Temperature Range- -40°F - 150°F (Fan assisted cooling)
Humidity (Non-Condensing)- Max 95%
ENCLOSURE
Material & Color- Aluminium (Blue RAL 5012)
Protection Category- IP22
Battery-Connections-
-
12/2000/80-50 = M8 Bolts
-
24/2000/50-50 = M8 Bolts
-
12/3000/120-50 = M8 Bolts 2 plus and 2 minus connections
-
24/3000/70-50 = M8 Bolts 2 plus and 2 minus connections
120V AC- Connection- Screw-terminal 6AWG (13mm²)
Weight-
-
12/2000/80-50 = 25lb
-
24/2000/50-50 = 25lb
-
12/3000/120-50 = 40lb
-
24/3000/70-50 = 40lb
Dimensions (HxWxD)-
-
12/2000/80-50 = 20.5" x 10.0" x 5.0"
-
24/2000/50-50 = 20.5" x 10.0" x 5.0"
-
12/3000/120-50 = 14.3" x 10.2" x 8.6"
-
24/3000/70-50 = 14.3" x 10.2" x 8.6"
STANDARDS
Safety-
-
12/2000/80-50 = UL 458, EN-IEC 60335-1, EN-IEC 60335-2-29
-
24/2000/50-50 = UL 458, EN-IEC 60335-1, EN-IEC 60335-2-29
-
12/3000/120-50 = UL 1741, UL 458, EN-IEC 60335-1, EN-IEC 60335-2-29
-
24/3000/70-50 = UL 1741, UL 458, EN-IEC 60335-1, EN-IEC 60335-2-29
Emission and Immunity-
-
12/2000/80-50 = EN-IEC 61000-3-2/3-3/, EN-IEC 61000-6-1/6-2/6-3
-
24/2000/50-50 = EN-IEC 61000-3-2/3-3/, EN-IEC 61000-6-1/6-2/6-3
-
12/3000/120-50 = EN-IEC 61000-3-2/3-3/, EN-IEC 61000-6-1/6-2/6-3
1) Can be adjusted to 50Hz
2) Protection Key
A) Output short circuit
B) Overload
C) Battery voltage to high
D) Battery voltage to low
E) Temperature to high
F) 120VAC on inverter output
G) Input voltage ripple to high
3) Non-linear load, crest factor 3:1
4) up to 75°F ambient
5) Switches off when non external AC Source available
6) Programmable relay that can a.o. be set for general alarm, DC under voltage or genset start/stop function
AC Rating- 120V/4A
DC Rating- 4A up to 35VDC, 1A up to 60VDC
7) A.o. to communicate with a Lithium Ion battery BMS