Midnite Solar Surge Protection Devices


Nominal Voltage- 0-300VDC

MCOV- 470V

VPR Line To Ground- 1200V

Suggested Placement- Off-grid PV combiners Charge Controller inputs up to 300VDC

Type- UL1449 4th Ed. Type 1

Thermal Disconnector- Internal Fuse

Response Time- <1 Micro Second

Performance

Surge Current Rating per Phase- 80kA

Short Circuit Current Rating- 10kA

Fusing- Individually fused MOVs

Thermal Fusing- Yes

Over Current Fusing- Yes

Operating Frequency- 0-500Hz

Mechanical Description

Enclosure- Polycarbonate UL94V-0

Environmental Rating- Type 4X

Connection Method- #12 AWG

Weight- 1lbs

Dimensions- 4.4"L x 3.8"W x 3.5"D

Mounting Method- 1/2" Conduit Knockout

Operating Altitude- Sea Level- 12,000' (3,658 Meters)

Storage Temperature- -40°F- 185°F (-40°C-85°C)

Operating Temperature- -40°F-185°F (-40°C-85°C)

Diagnostics

Blue Status LED, One Per Leg

Listings and Performance-

UL Standard for Safety, UL 1449 Surge Protective Devices-Fourth Edition CSA C22.2 No. 8-M1986 Electromagnetic Interference (EMI) Filters, Fourth Edition.

Nominal Voltage- 0-250VAC

MCOV- 470V

VPR Line To Ground- 1200V

Suggested Placement- 120/240 VAC Circuits

Type- UL1449 4th Ed. Type 1

Thermal Disconnector- Internal Fuse

Response Time- <1 Micro Second

Performance

Surge Current Rating per Phase- 80kA

Short Circuit Current Rating- 10kA

Fusing- Individually Fused MOVs

Thermal Fusing- Yes

Over Current Fusing- Yes

Operating Frequency- 0-500Hz

Mechanical Description

Enclosure- Polycarbonate UL94V-0

Environmental Rating- Type 4X

Connection Method- #12 AWG

Weight- 1lbs

Dimensions- 4.4"L x 3.8"W x 3.5"D

Mounting Method- 1/2" Conduit Knockout

Operating Altitude- Sea Level- 12,000' (3,658 Meters)

Storage Temperature- -40°F-185°F (-40°C-85°C)

Operating Temperature- -40°F-185°F (-40°C-85°C)

Diagnostics

Blue Status LED, One Per Leg

Listing And Performance-

UL Standard for Sagety, UL 1449 Surge Protective Devices-Fourth Edition CSA C22.2 No. 8-M1986 Electromagnetic Interference (EMI) Filters, Fourth Edition

Nominal Voltage- 0-480VAC 0-600VDC

MCOV- 780V

VPR Line To Ground- 1800V

Suggested Placement- 316V/480 VAC circuits Grid-tie PV combiners Grid-tie inverter input Non-Isolated Inverters

Type- UL1449 4th Ed. Type 1

Thermal Disconnector- Internal Fuse

Response Time- <1 Micro Second

Performance

Surge Current Rating Per Phase- 80kA

Short Circuit Current Rating- 10kA

Fusing- Individually fused MOVs

Thermal Fusing- Yes

Over Current Fusing- Yes

Operating Frequency- 0-500Hz

Mechanical Description

Enclosure- Polycarbonate UL94V-0

Environmental Rating- Type 4X

Connection Method- #12 AWG

Weight- 1lbs

Dimensions- 4.4"L x 3.8"W x 3.5"D

Mounting Method- 1/2" Conduit Knockout

Operating Altitude- Sea Level- 12,000' (3,658 Meters)

Storage Temperature- -40°F-185°F (-40°C-85°C)

Operating Temperature- -40°F-185°F (-40°C-85°C)

Diagnostics

Blue Status LED, One Per Leg

Listings and Performance-

UL Standard for Safety, UL 1449 Surge Protective Devices-Fourth Edition CSA C22.2 No. 8-M1986 Electromagnetic Interference (EMI) Filters, Fourth Edition