Sol-Ark All-In-One Inverters


The Sol-Ark Limitless Inverter is an all in one pre-wired systems that contain the inverter, charge controller, and more all in one package! Minimal hardware is required. That means NO fuses, No breakers, and NO combiner boxes necessary! Sol-Ark also provides Fleet Management meaning you have remote access features to multiple units/installations as was as an app. So you are never out of touch and can quickly repair or adjust any system without being on site!

Sol-Ark is a Veteran Owned business that creates products that are easy to install. They also provide unparalleled support from techs and engineers right here in the US.

 

Solar

Input Power = 5,000W

Max Allowed PV Power = 3,250W+3,250W=6,500W

Max DC Voltage (Voc) = 500V@18A, 450V@20A

MPPT Voltage Range =150-425V

Starting Voltage = 125V

Number of MPPT = 2

Max Solar Strings Per MPPT = 2

Max DC Current Per MPPT (Self Limiting) = 10A

Max AC Coupled Input (micro/string inverters) = 9,600W

Battery (Optional)

Type = Lead-Acid or Li-Ion

Nominal DC Input = 48V

Capacity = 50-9900Ah

Voltage Range = 43.0-63.0V

Continuous Battery Charging Output = 120A

Charging Curve = 3-Stage w/ Equalization

Grid to Batt Charging Efficiency = 96.0%

External Temperature Sensor Included

Current Shunt for Accurate % SOC is Integrated

External Gen Start Based on Voltage or % SOC is Integrated

Communication to Lithium Battery = CanBus & RS485 

AC Output Power 5kW On-Grid & Off-Grid

Connections = 120/240/208V Split Phase

Continuous AC Power to Grid (On-Grid) = 5,000W 20.8A-L (240V)

Continuous AC Power to Load (Off-Grid) = 5,000W 20.A-L (240V)

Surge AC Power (10sec) = 16,000VA L-L (240V)

Surge AC Power (100ms) = 25,00VA L-L (240V)

Parallel Stacking = No

Frequency = 60/50Hz

Continuous AC Power with Grid or Generator = 

  • 15,120W 63A L-L (240V)
  • 7,560W 63A L-N (120V)

CEC Efficiency = 96.5% (Peak 97.5%)

Idle Consumption Typical-No Load = 60W

Sell Back Power Modes Limited to Household/Fully Grid-Tied

Design (DC to AC) Transformerless DC

Response Time (Grid-Tied to Off-Grid) = 4ms

Power Factor = +/- 0.9-1.0

General

Dimensions (H x W x D) = 30.0" x 18.3" x 10.0"

Weight = 78lbs

Enclosure = NEMA 3R

Ambient Temperature = -25-55°C,,>45°C Derating

Installation Style = Wall-Mounted 

WI-FI & LAN Communication Included

Standard Warranty (certified by HALT Testing) = 5 Years

Protections & Certifications

Electronics Certified Safety by SGS Labs To NEC & UL Specs - NEC 690.4B & NEC 705.4/6 Yes

Grid Sell Back - UL1741-2010/2018, IEE-E1547a-2003/2014, FCC 15 Class B, UL1741SA, CA Rule 21 HECO Rule 14H                                                                                                  Yes

PV DC Disconnect Switch- NEC 240.15 Integrated

Ground Fault Detection - NEC 690.5 Integrated

PV Rapid Shutdown Control - NEC 690.12 Integrated

PV Arc Fault Detection - NEC 690.11 Integrated

PV Input Lightning Protection Integrated

PV String input Reverse Polarity Protection Integrated

AC Output Breakers- 63A Integrated

250A Battery Breaker/ Disconnect Integrated

Surge Protection DC Type II/ AC Type II

Solar

Maxed Allowed PV Power= 5,500+5,500=11,000W

Max PV Power Delivered to Battery & AC Outputs= 8,000W 

Max DC Voltage (Voc)= 500V @ 18A, 450V @ 20A

MPPT Voltage Range= 150-425a

Starting Voltage= 125V

Number of MPPT= 2

Max Solar Strings Per MPPT= 2

Max DC Current per MPPT (Self limiting)= 20A

Max AC Coupled input (Micro/String inverters)= 9,600W 

Battery (optional)

Type= Lead-Acid or Li-Ion

Nominal DC Input= 48V

Capacity= 50-9900Ah

Voltage Range= 43.0-63.0V

Continuous Battery Charging Output= 185A

Charging Curve= 3-stage w/ Equalization 

Grid to Batt Charging Efficiency= 96.0%

External Temperature Sensor= Included

Current Shunt for Accurate % SOC= Integrated

External Gen Start Based on Voltage or %SOC= Integrated 

Communication to Lithium Battery= CanBus & RS485

AC Output Power 8kW On-Grid & Off-Grid

Connections= 120/240/208V Split Phase

Continuous AC Power to Grid (On-Grid)= 8,000W 33.3A-L (240V)

Continuous AC Power to Load (Off-Grid)= 8,000W 33.3A-L (240V)

Surge AC Power (10sec)= 16,000VA L-L (240V)

Surge AC Power (100ms)= 25,000VA L-L (240V)

Parallel Stacking= No

Frequency= 60/50Hz

Continuous AC Power with Grid or Generator

  • 15,120W 63A L-L (240V)
  • 7,560W 63A L-N (120V)

CEC Efficiency =96.5% (Peak 97.5%)

Idle Consumption= Typical-No Load 60W

Sell Back Power Modes= Limited to Household/Fully Grid-Tied

Design (DC to AC)= Transformerless DC

Response Time (Grid-Tied to Off-Grid)= 4ms

Power Factor= +/-0.9-1.0

General

Dimensions= (H x W x D) 30.0"x18.3"x10.0"

Weight= 78lbs

Enclosure= NEMA 3R

Ambient Temperature= -25-55°C, >45°C Derating

Installation Style= Wall-Mounted

Wi-Fi & LAN Communication= Included

Standard Warranty (verified by HALT Testing)= 5 Years

Protections & Certifications

Electronics Certified Safty by SGS Labs to NEC & UL Specs - NEC 690.4B & NEC 705.4/6= Yes

Grid Sell Back -UL1741-2010/2018,IEE-E1547A-2003/2014,FCC 15 Class B, UL1741SA, CA Rule 21, HECO Rule 14H =Yes

PV DC disconnect Switch - NEC 240.15= Integrated

Ground Fault Detection - NEC 690.5= Integrated

PV Rapid Shutdown Control - NEC 690.12= Integrated

PV Arc Fault Detection - NEC 690.11= Integrated 

PV Input Lightning Protection= Integrated

PV String Input Reverse Polarity Protection= Integrated 

AC Output Breakers= - 63A

250A Battery Breaker/ Disconnect= Integrated

Surge Protection= DC Type II / AC Type II

Solar

Max Allowed PV Power 6,500W+6,500W=13,000

Max PV Power Delivered to Battery & AC Outputs= 12,000W 

Max DC Voltage (Voc)= 500V @ 18A, 450V @ 20A

MPPT Voltage Range= 150-425V

Starting Voltage= 15V

Number of MPPT= 2

Max Solar Strings Per MPPT= 2

Max DC Current Per MPPT (Self Limiting)= 20A

Max AC Coupled Input (Micro/String Inverters)= 9,600W

Battery (Optional)

Type= Lead-Acid or Li-Ion

Nominal DC Input= 48V

Capacity= 50-9900Ah

Voltage Range= 43.0-63.0V

Continuous Battery Charging Output= 185A

Charging Curve= 3-Stage w/ Equalization 

Grid to Batt Charging Efficiency= 96.0%

External Temperature Sensor= Included

Current Shunt for Accurate % SOC= Integrated 

External Gen Start Based on Voltage or %SOC= Integrated 

Communication to Lithium Battery= CanBus & RS485

AC Output Power 9kW On-Grid & Off-Grid

Connections= 120/240/208V Split Phase 

Continuous AC Power to Grid (on-Grid)= 9,000W 37.5A-L (240V)

Continuous AC Power to Load (off-Grid)= 9,000W 37.5A-L (240V)

Surge AC Power (10sec)=16,000VA L-L (240V)

Surge AC Power (100ms)= 25,000VA L-L (240)

Parallel Stacking= Yes

Frequency= 60/50Hz

Continuous AC Power with Grid or Generator=

  • 15,120W 63A L-L (240V)
  • 7,560W 63A L-N (120)

CEC Efficiency= 96.5% (Peak 97.5%)

Idle Consumption= Typical- No Load 60W

Sell Back Power Modes= Limited to Household/Fully Grid-Tied

Design (DC to AC)= Transformerless DC

Response Time (Grid-Tied to Off-Grid)= 4ms

Power Factor= +/- 0.9-1.0

General

Dimensions= (H x W x D) 30.0"x18.3"x10.0"

Weight= 78lbs

Enclosure= NEMA 3R

Ambient Temperature= -25-55°C,>45°C Derating

Installation Style= Wall-Mounted

Wi-Fi & Lan Communication= Included

Standard Warranty (verified by HALT Testing)= 10 Years

Protections & Certifications

Elections Certified Safety by SGS Labs to NEC & UL Specs - NEC 690.4B & NEC 705.4/6= Yes

Grid Sell Back- UL1741-2010/2018, IEE-E1547A-2003/2014, FCC 15 Class B, UL1741SA, CA Rule 21, HECO Rule 14H= Yes

PV DC Disconnect Switch-NEC240.15= Integrated 

Ground Fault Detection-NEC 690.5= Integrated

PV Rapid Shutdown Control-NEC 690.12= Integrated 

PV Arc Fault Detection-NEC 690.11= Integrated

PV Input Lightning Protection= Integrated

PV String Input Reverse Polarity Protection= Integrated 

AC Output Breakers-63A= Integrated

250A Battery Breaker / Disconnect= Integrated

Surge Protection= DC Type II / AC Type II

Solar

Max Allowed PV Power= 19,500W

Max PV Power Delivered to Battery & AC Outputs= 15,000W

Max DC Voltage (Voc)= 500V@26A

MPPT Voltage Range= 125-425V

Starting Voltage= 125V

Number of MPPT= 3

Max Solar Strings Per MPPT= 2

Max DC Current per MPPT (Self Limiting)= 26A

Max AC Coupled Input (Micro/String Inverters)= 19,200W

Battery (Option)

Type= Lead-Acid or Li-Ion

Nominal DC Input= 48V

Capacity= 50-9900Ah

Voltage Range= 43.0-63.0V

Continuous Battery Charging Output= 275A

Charging Curve= 3-Stage w/ Equalization

Grid to Batt Charging Efficiency= 96.0%

External Temperature Sensor= Included 

Current Shunt for Accurate % SOC= Integrated 

External Gen Start Based on Voltage or %SOC= Integrated

Communication to Lithium Battery= CanBus & RS485

AC Output Power 15kW On-Grid & Off-Grid

Connections= 120/240/208V Split Phase 

Continuous AC Power to Grid (On-Grid)=15,000W 62.5A-L (240V)

Continuous AC Power to Load (Off-Grid)= 12,000W 50A-L (240V)

Surge AC Power (10sec)= 24,000W 200A L-L(240V)

Surge AC Power (100ms)= 30,000VA L-L(240V)

Parallel Stacking= Yes up to 12

Frequency= 60/50Hz

Continuous AC Power with Grid or Generator

  • 48,000W 200A L-L(240V)
  • 24,000W 200A L-N(120V)

CEC Efficiency= 96.5% (Peak 97.5%)

Idle Consumption Typical-No Load= 90W

Sell Back Power Modes= Limited to Household/Fully Grid-Tied

Design (DC to AC)= Transformerless DC

Response Time (Grid-Tied to Off-Grid)= 5ms

Power Factor= +/- 0.9-1.0

General

Dimensions (H x W x D)= 31.8"x18.3"x10.9"

Weight (package)= 135lbs

Enclosure= IP65/Nema 3R

Ambient Temperature= -40~60°c,>45°c Derating

Installation Style= Wall-Mounted

Wi-Fi & LAN Communication= Included

Standard Warranty (verified by HALT Testing)= 10 Years

Protections & Certifications

Electronics Certified Saftey by SGS Labs to NEC & UL Specs- NEC 690.4B & NEC 705.4/6= Yes

Grid Sell Back-UL1741-2010/2018, IEE-E1547a-2003/2014, FCC 15 Class B, UL1741SB= Yes

PV DC Disconnect Switch-NEC 240.15= Integrated

Ground Fault Detection-NEC 690.5= Integrated

PV Rapid Shutdown Control-NEC 690.12= Integrated

PV Arc Fault Detection-NEC 690.11= Integrated

PV Input Lightning Protection= Integrated

PV String Input Reverse Polarity Protection= Integrated

AC Output Breakers-200A= Integrated 

200A x 2 Battery Breaker/Disconnect= Integrated

Surge Protection= DC Type II/ AC Type II