Remote on/off
The remote on/off eliminates the need for a high current switch in the input wiring. The remote on/off can be operated with a low power switch or by for example the engine run/stop switch (see manual). All models are short circuit proof and can be paralleled to increase output current. An unlimited number of units can be connected in parallel. IP43 protection When installed with the screw terminals oriented downwards. Screw terminals No special tools needed for installation. Input fuse On 12V and 24V input models only.
Input Voltage Range- 40-70V
Under Voltage Shut Down- 28V
Under Voltage Restart- 30V
Nominal Output Voltage- 12.2V
Output Voltage Adjust Range- 10-15V
Output Voltage Tolerance- +/- 0.2V
Output Noise- 2mV rms
Cont. Output Current At Nominal Output Voltage And 40°C- 30A
Maximum Output Current (10S) At Nominal Output Voltage Minus 20%- 40A
Short Circuit Output Current- 60A
Cont. Output Power At 25°C- 430W
Cont. Output Power At 40°C- 360W
Efficiency- 87%
Off Load Current- <80 mA
Galvanic Isolation- 200 VDC between input, output, and case.
Operating Temperature Range- -20 to +50°C (derate 3% per °C above 40°C)
Humidity- Max. 95% non-condensing
DC Connection- Screw Terminals
Maximum Cable Cross-Section- 16 mm² (AWG6)
Weight- 3 lbs
Dimensions HxWxD- 5.1 x 7.3 x 3.2 Inches
Standards-
Safety- EN 60950
Emission- EN 61000-6-3, EN55014-1
Immunity- EN 61000-6-2, EN 61000-6-1, EN 55014-2
Automotive Directive- ECE R10-5
If set to nominal or lower than nominal, the output voltage will remain stable within the specified input voltage range (buck-boost function). If the output voltage is set higher than nominal by a certain percentage, the minimum input voltage at which the output voltage remains stable (does not decrease) increases by the same percentage.