Victron Energy Smart BatteryProtect With Bluetooth


The Smart BatteryProtect disconnects the battery from non-essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine. When using Bluetooth to program the Smart BatteryProtect any required engage/disengage levels can be set.
Alternatively, one of nine predefined engage/disengage levels can be set with the programming pin (see manual). If required, Bluetooth can be disabled. The Smart BatteryProtect is a uni-directional device. It can only deal with current in one direction, so either current to a load, or current from a charger, but not both currents at the same time. In addition to this, current only can only flow from the IN terminal to the OUT terminal. In case of use with a load, the battery connects to the IN terminal, and in case of use with a charger, the charger connects to the IN terminal.

Maximum Continuous Load Current- 

  • 65A - 65A
  • 100A - 100A
  • 220A - 220A

Peak Current (During 30 Seconds)-

  • 65A - 250A
  • 100A - 600A
  • 220A - 600A

Operating Voltage Range - 6 - 35V 

Current Consumption-

  • Ble On- When on: 1.4mA, When off or low voltage shut down 0.9mA
  • Ble Off- When on: 1.2mA, When off or low voltage shut down 0.7mA

Alarm Output Delay- 12 Seconds

Maximum Load On Alarm Output- 50mA (short circuit proof)

Load Disconnect Delay- 90 Seconds (Immediate if triggered by the VE.Bus BMS)

Load Reconnect Delay- 30 Seconds

Default Thresholds- 

  • Disengage- 10.5V or 21V
  • Engage- 12V or 24V

Operating Temperature Range- Full load: -40°C - 40°C (Up to 60% of nominal load at 50°C)

IP Rating-

  • Electronics- IP67 (potted)
  • Connections- IP00

Connections-

  • 65A - M6
  • 100A - M8
  • 220A - M8

Mounting Torque- 

  • 65A - 5Nm
  • 100A - 9Nm
  • 220A - 9Nm

Weight- 

  • 65A - 0.5lbs
  • 100A - 0.6lbs
  • 220A - 1.8lbs

Dimensions (HxWxD)-

  • 65A - 1.6"  x 1.9" x 4.2"
  • 100A - 2.4" x 1.7" x 4.6"
  • 220A - 2.5" x 4.9" x 4.8"